FFC APPRENTICESHIP CHEMICAL PAST PAPER 2024
FFC 5 years
Past Papers Click here
Show Answers
چار آپشن میں سے کسی ایک پر کلک کرنے سے جواب سرخ ہو جائے گا۔
By boiling point
By charge-to-size ratio
By size exclusion
By partitioning between a stationary phase and a mobile phase
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
High-performance liquid chromatography (HPLC) separates components in a mixture by partitioning between a stationary phase and a mobile phase.
Partitioning:
In HPLC, the sample mixture is introduced into a column packed with a stationary phase (a solid material) and a liquid mobile phase flows through the column.
Differential retention:
Different components in the mixture have different affinities for the stationary phase and the mobile phase.
Separation:
As the mobile phase flows through the column, the components with a stronger affinity for the stationary phase will spend more time interacting with it,
Resulting in slower movement through the column, while the components with a weaker affinity will move faster
Peak maximum in the original spectrum
Peak minimum in the original spectrum
Baseline level in the original spectrum
Peak inflection point in the original spectrum
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
In derivative spectroscopy, a zero-crossing point occurs where the derivative spectrum crosses the zero axis,
Indicating a change in the slope of the original spectrum.
This change in slope corresponds to a peak inflection point,
The point where the curvature of the original spectrum changes from concave up to concave down, or vice versa.
تجزیاتی آلات کو باقاعدگی سے کیلیبریٹ کرنا کیوں ضروری ہے؟
To improve instrument sensitivity
To ensure accurate measurements
To prolong instrument lifespan
To reduce analysis time
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Regular calibration compares an instrument's readings to a known standard , allowing for any deviations to be detected and corrected.
This process is crucial for maintaining the integrity and reliability of all quantitative data in a laboratory.
The molecular mass
The presence of C=O bonds
The presence of O-H bonds
The identity of a compound through comparison with other spectra
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Infrared (IR) spectroscopy is excellent at identifying functional groups in a molecule,
like C=O and O-H bonds, by detecting their characteristic vibrational frequencies.
It can also help identify a compound by comparing its IR spectrum to reference spectra of known compounds.
However, IR spectroscopy does not provide information about the molecular mass of a compound.
0.8 - 500μm
400 - 100nm
380 - 750nm
0.01 - 10nm
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
UV spectroscopy utilizes wavelengths in the ultraviolet range, which is typically between 100 and 400 nanometers.
Optio n B correctly represents this range,
While the other choices correspond to different regions of the electromagnetic spectrum:
A. 0.8 - 500μm: This range falls within the infrared region.
C. 380 - 750nm: This is the visible light range.
D. 0.01 - 10nm : This range is associated with X-rays.
The temperature at which the sample starts to decompose
The temperature at which the sample reaches its maximum weight
The temperature at which the sample completes its decomposition
The temperature at which the sample melts
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
The onset temperature in a thermogravimetric analysis (TGA) curve indicates the point at which a material starts to experience a significant mass loss due to:
Thermal events such as decomposition, Evaporation of volatiles Or the initiation of reactions This temperature serves as an important measure of a material's thermal stability, although it can be influenced by factors like heating rate, sample size, and atmosphere.
تفریق اسکیننگ کیلوری میٹری میں بیس لائن اصلاح کا بنیادی مقصد کیا ہے؟
To eliminate instrumental noise
To adjust for variations in heat flow
To correct for changes in temperature
To improve the accuracy of heat capacity measurements
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
The primary purpose of baseline correction in differential scanning calorimetry (DSC) is to adjust for variations in heat flow.
Baseline correction in DSC removes any extraneous heat flow signals that are not related to the sample's thermal events.
This allows for the accurate determination of the heat flow changes associated wit h specific transitions like melting or glass transitions.
The baseline is essentially a reference point against which the sample's heat flow is compared.
مندرجہ ذیل میں سے کون سا راڈ کے سائز کا بیکٹیریا ہے؟
Coccus
Bacillus
Spirillum
None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Bacillus refers to rod-shaped bacteria.
Coccus are spherical .
Spirillum are spiral -shaped.
250
300
350
375
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
To find out what number 15% of is equal to 45, you can set up the equation:
0.15 × X = 45 0.15 × X = 45
To solve for X (the number we're looking for), divide both sides by 0.15:
X = 45 0.15 X = 0.15 45
X = 300 X = 300
So, 15% of 300 is equal to 45.
ان میں سے کون سی حواس کم از کم انسانوں میں تیار ہوئی ہیں۔
Listen
Hearing
Smell
Sight
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Vision is the least developed sense at birth, as the womb i s a dark place and there is little opportunity for developmen t.
Hearing: Develops relatively well during pregnancy, allowing babies to hear sounds from around the 20th week.
Touch: Also develops fairly well in utero, providing comfort and a sense of security.
Smell and Taste: These senses are closely linked and are important for newborns to recognize their mother's breastmilk and establish bonding.